P0010
P0010Inlet camshaft driver - open circuit
Diagnostic conditions
- Battery positive voltage between 10 V and 16 V
- Time after engine starts: 10 seconds
Possible cause of fault
- Open circuit in control line
- Open circuit in voltage supply
- Fuse F9 faulty (fuse carrier in radiator tank E-box)
- Connection KE 7 disconnected
- Inlet camshaft adjuster faulty (internal open circuit)
- DME control module faulty
Affected pins
DME control module plug B, pin 115, and pin 2 of inlet camshaft adjuster plug
Diagnosis/troubleshooting
NOTE: The wire for fuse F9 and pin 1 of the inlet camshaft adjuster plug is routed via pin 6 of connection KE 7