P0160

P0160

Oxygen Sensor After TWC, Bank 2 - Open Circuit

Diagnosis conditions
- Exhaust temperature between 250 °C and 750 °C
- Battery positive voltage between 10 V and 16 V
- 200 seconds after engine start-up

Possible fault cause
- Open circuit in the signal wire and/or ground wire of oxygen sensor
- Loose contact in connector
- Open circuit in B+ and/or negative line of the oxygen sensor heating
- Oxygen sensor faulty (heating resistance too high)
- DME control module faulty

Affected terminals
DME control module connector A, pin 10, and oxygen sensor connector after TWC bank 2, pin 3
DME control module connector A, pin 11, and oxygen sensor connector after TWC bank 2, pin 4

Diagnosis/troubleshooting

NOTE: Do not use contact spray on the oxygen sensor plug connections, as this may cause irreparable damage to the wiring (blocking the reference air channels).

NOTE: Do not confuse oxygen sensor ahead of catalytic converter and oxygen sensor after catalytic converter as this will cause implausible fault entries.

Distinguishing feature of both sensors:

Oxygen sensor ahead of catalytic converter (LSU) has a 6-pole connector






Oxygen sensor after catalytic converter (LSF) has a 4-pole connector






NOTE: If connector A is disconnected from the DME control module and the ignition is or was switched on, the 'DME Control Module TIMEOUT' fault is recorded in many control modules.

NOTE: If control module connector A was disconnected from the DME in the course of troubleshooting or if the voltage supply was interrupted elsewhere (battery, fuse), the throttle adjusting unit must be adapted.