P1181
P1181Positive Crankcase Ventilation Heater Output Stage - Below Limit
Diagnosis conditions
- Battery positive voltage between 10 V and 16 V
- Time elapsed after engine start-up greater than 1 second
Possible fault cause
- Short circuit to ground in triggering wire
- Positive crankcase ventilation heater faulty (short circuit to engine ground)
- DME control module faulty
Affected pin
DME control module connector B, pin 121, and positive crankcase ventilation heater connector, pin 2
Diagnosis/troubleshooting
NOTE:
- The wiring diagnosis proceeds in the DME control module even if the positive crankcase ventilation heater is switched off (i.e. at an external air temperature above 3 °C).
- The positive crankcase ventilation heater is activated continuously if a fault occurs when measuring the external air temperature.