P1915
P1915Additional Water Pump Relay Output Stage - Above Limit
NOTE: In naturally aspirated V8 engines, the relay for the additional water pump is only activated by the air-conditioning control module.
Diagnostic conditions
- Battery voltage between 10 V and 16 V
- Time after the engine is started longer than 10 seconds
Possible cause of fault
- Short circuit to B+ in triggering wire of additional water pump relay
- Additional water pump relay faulty
- DME control module faulty
Affected pins
DME control module connector A, pin 48, and additional water pump relay connector, pin 2
Diagnosis/troubleshooting
NOTE: If connector A is disconnected from the DME control module and the ignition is or was switched on, the 'DME Control Module Timeout' fault is recorded in many control modules.
NOTE: If control module connector A was disconnected from the DME in the course of troubleshooting or if the voltage supply was interrupted elsewhere (battery, fuse), the throttle adjusting unit must be adapted.