Operation CHARM: Car repair manuals for everyone.

P2128

P2128

Throttle Position Sensor 2 - Above Limit

Diagnostic conditions
- Engine running

Possible cause of fault
- Short circuit to B+ in wiring harness
- Throttle adjusting unit faulty
- DME control module faulty

NOTE: When this fault occurs, the value from the accelerator module is limited to 30 % and the dynamic is reduced.

Affected terminals
DME control module connector B, pins 83, 84 and 98

Pin assignment on the throttle adjusting unit






Diagnosis/troubleshooting