Expansion Valve: Service and Repair
WM 877019 Removing and installing expansion valve
Technical values
Preliminary work
Preliminary work for expansion valve
-> 852219 Removing and installing cover - section on "removing" 85221900 Removing and installing cover
-> 870317 Draining and filling in refrigerant Service and Repair
Removing expansion valve
1. Unscrew fastening nuts -1-.
Unscrewing fastening nuts
2. Remove the bracket for the two refrigerant lines and pull the refrigerant lines out of the expansion valve.
3. Undo the two fastening screws on the expansion valve and remove expansion valve.
Fastening screws on expansion valve
Installing expansion valve
Information
Before re-installing the component, check the O-rings of the refrigerant lines for damage and replaced them if necessary.
Wet the O-rings of the refrigerant lines with refrigerant oil.
Do not open the plugs for the lines and connections until shortly before installation.
Close off all lines and connections using suitable plugs during removal.
1. Carefully push expansion valve onto refrigerant lines from evaporator - do not tilt.
2. Insert and tighten the two fastening screws. => tightening torque: 9 Nm (ftlb.) (6.5)
Fastening screws on expansion valve
3. Position refrigerant lines on expansion valve and press into place - do not tilt.
4. Position bracket for refrigerant lines and secure with the fastening nuts -1-. => tightening torque: 6 Nm (ftlb.) (4.5)
Screwing in fastening nuts
Subsequent work
Rework on expansion valve
-> 870317 Draining and filling in refrigerant Service and Repair
-> 852219 Removing and installing cover - section on "installing" 85221900 Removing and installing cover