Subaru Select Monitor

Subaru Select Monitor

OPERATION

1. Prepare the Subaru Select Monitor kit.






2. Prepare the personal computer which has been installed the Subaru Select Monitor.
3. Connect the USB cable between SDI (Subaru Diagnosis Interface) and USB port on the personal computer (dedicated port for the Subaru Select Monitor).

NOTE: The dedicated port for the Subaru Select Monitor means the USB port which was used to install the Subaru Select Monitor.

4. Connect the diagnosis cable to SDI.
5. Connect the SDI to data link connector located in the lower portion of the instrument panel (on the driver's side).






6. Start a PC.
7. Turn the ignition switch to ON (engine OFF), and run the "PC application for Subaru Select Monitor".

INSPECTION

1. COMMUNICATION FOR INITIALIZING IMPOSSIBLE DETECTING CONDITION:

Harness connector malfunction

TROUBLE SYMPTOM:
Not communicable with Subaru Select Monitor.

WIRING DIAGRAM:






Step 1-4:




Step 5-12:






CAUTION: When replacing the body integrated unit on the model with immobilizer system, the registration of immobilizer is necessary. For registration procedures, refer to the "PC application help for Subaru Select Monitor".