Operation CHARM: Car repair manuals for everyone.

Steering Shaft Coupler: Testing and Inspection

INSPECTION

1) Check for wear, damage or any other faults. Replace as necessary

Service limit:
Universal joint play: 0 mm (0 in)





2) Measure the swing torque of universal joint.

Service limit:
Maximum load: 3.8 N (0.39 kgf, 0.86 lbf) or less





Service limit:
Maximum load: 3.8 N (0.39 kgf, 0.86 lbf) or less





Service limit:
Maximum load: 7.3 N (0.74 kgf, 1.64 lbf) or less





Service limit:
Maximum load: 7.3 N (0.74 kgf, 1.64 lbf) or less