Component Tests and General Diagnostics
Power Supply and Ground Circuit Check [Combination Meter]
Regarding Wiring Diagram information, refer to [Meter: Wiring Diagram] Meter.
1. CHECK FUSES
Check for blown combination meter fuses.
Is the inspection result normal?
YES
GO TO 2
NO
If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse.
2. POWER SUPPLY CIRCUIT CHECK
1 Disconnect combination meter connector M24.
2 Check voltage between combination meter harness connector M24 terminals 3, 16 and ground.
Is the inspection result normal?
YES
GO TO 3
NO
Check harness for open between combination meter and fuse.
3. GROUND CIRCUIT CHECK
1 Turn ignition switch OFF.
2 Check continuity between combination meter harness connector M24 terminals 13, 23 and ground.
Is the inspection result normal?
YES
Inspection End.
NO
Check ground harness.