P0156
DTC P0156 OXYGEN SENSOR CIRCUIT MALFUNCTION (BANK 2 SENSOR 2)CIRCUIT DESCRIPTION
DTC Detection Condition:
The heated oxygen sensor (HO2S) is used to monitor oxygen in the exhaust gas. For optimum catalyst operation, the air-fuel mixture (air-fuel ratio) must be maintained near the ideal "stoichiometric" ratio. The HO2S output voltage changes suddenly in the vicinity of the stoichiometric ratio. The ECM adjusts the fuel injection time so that the air-fuel ratio is nearly stoichiometric.
The HO2S generates a voltage between 0.1 and 0.9 volts in response to oxygen in the exhaust gas. If the oxygen in the exhaust gas increases, the air-fuel ratio becomes "Lean". The ECM interprets Lean when the HO2S voltage is below 0.45 volts. If the oxygen in the exhaust gas decreases, the air-fuel ratio becomes "Rich". The ECM interprets Rich when the HO2S voltage is above 0.45 volts.
HINT:
- Bank 1 refers to the bank that includes cylinder No.1.
- Bank 2 refers to the bank that does not include cylinder No.1.
- Sensor 2 refers to the sensor farthest away from the engine assembly.
MONITOR DESCRIPTION
Monitor Strategy:
Typical Enabling Conditions Part 1:
Typical Enabling Conditions Part 2:
Typical Malfunction Thresholds Part 1:
Typical Malfunction Thresholds Part 2:
Component Operating Range:
O2S Test Result:
The heated oxygen sensor (HO2S) outputs 0 - 1 volt of the voltage. The voltage varies with oxygen density in the exhaust gas. The ECM measures the voltage to monitor the HO2S.
Voltage
The ECM counts the time while the HO2S voltage is lower than 0.05 volts. When the time exceeds a malfunction threshold, the ECM illuminates the MIL and sets DTC P0136 or P0156 (2trip detection logic).
Switching
The ECM counts the frequency of the HO2S switching. When the HO2S does not switch for a certain period, the ECM illuminates the MIL and sets DTC P0136 or P0156 (2trip detection logic).
Low voltage
The ECM measures the HO2S voltage. When the voltage is lower than 0.03 volts for 90 seconds, the ECM illuminates the MIL and sets DTC P0137 or P0157.
Voltage during fuel-cut
The ECM measure the HO2S voltage during the fuel-cut. When the voltage does not reach to 0.2 volts during the fuel-cut, the ECM illuminates the MIL and sets DTC P0138 or P0158 (2trip detection logic).
High voltage
The ECM measures the HO2S voltage. When the voltage is higher than 1.2 volts for 10 seconds, the ECM illuminates the MIL and sets DTC P0138 or P0158.
Wiring Diagram:
CONFIRMATION DRIVING PATTERN
a. Connect the hand-held tester to the DLC3.
b. Switch the hand-held tester from the normal mode to the check (test) mode.
c. Start the engine and warm up the engine until engine coolant temperature is more than 75°C.
d. Drive the vehicle at 38 mph (60 km/h) or more for 40 seconds or more.
e. Let the engine idle for 10 seconds or more.
f. Perform steps (d) to (e) 12 times.
HINT: If a malfunction exists, the MIL will illuminate during step (f).
NOTE: If the conditions in this test are not strictly followed, detection of a malfunction will not occur. If you do not have a hand-held tester, turn the ignition switch OFF after performing steps from (c) to (f), then perform steps from (c) to (f) again.
Step 1 - 3:
Step 4 - 6:
Step 7 - 8:
Step 9:
Step 10 - 14:
Step 15:
INSPECTION PROCEDURE
HINT:
Hand-held tester only:
It is possible the malfunctioning area can be found using the ACTIVE TEST A/F CONTROL operation. The A/F CONTROL operation can determine if the A/F sensor, heated oxygen sensor or other potential trouble areas are malfunctioning or not.
a. Perform the ACTIVE TEST A/F CONTROL operation.
HINT: The A/F CONTROL operation lowers the injection volume 12.5% or increases the injection volume 25%.
1. Connect the hand-held tester to the DLC3 on the vehicle.
2. Turn the ignition switch ON.
3. Warm up the engine by running the engine at 2,500 rpm for approximately 90 seconds.
4. Enter the following menus: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / A/F CONTROL.
5. Perform the A/F CONTROL operation with the engine idle (press the right or left button).
Result:
A/F sensor reacts in accordance with increase and decrease of injection volume:
+25% --> RICH output: Less than 3.0 V
-12.5% --> LEAN output: More than 3.35 V
Heated oxygen sensor reacts in accordance with increase and decrease of injection volume:
+25% --> RICH output: More than 0.55 V
-12.5% --> LEAN output: Less than 0.4 V
NOTE: The A/F sensor output has a few seconds of delay and the heated oxygen sensor output has about 20 seconds of delay at maximum.
The following A/F CONTROL procedure enables the technician to check and graph the voltage outputs of both the A/F sensor and the heated oxygen sensor.
For displaying the graph, enter "ACTIVE TEST / A/F CONTROL / USER DATA", select "AFS B1S1 and O2S B1S2" by pressing "YES" and push "ENTER". Then press "F4".
HINT: Read freeze frame data using the hand-held tester or the OBD II scan tool. Freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
CHECK FOR INTERMITTENT PROBLEMS
HINT:
Hand-held tester only:
Inspect the vehicle's ECM using check mode. Intermittent problems are easier to detect when the ECM is in check mode with hand-held tester. In check mode, the ECM uses 1 trip detection logic, which has a higher sensitivity to malfunctions than normal mode (default), which uses 2 trip detection logic.
a. Clear the DTCs.
b. Set the check mode.
c. Perform a simulation test.
d. Check the connector and terminal.
e. Wiggle the harness and the connector.