Operating Light Control Rheostat Does Not Change Light Brightness
METER / GAUGE SYSTEM: Operating Light Control Rheostat does not Change Light Brightness
Operating Light Control Rheostat does not Change Light Brightness
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. INSPECT COMBINATION METER ASSEMBLY
(a) Disconnect the combination meter connectors.
(b) Measure the voltage according to the value(s) in the table below.
Standard voltage:
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR (COMBINATION METER ASSEMBLY - ENGINE ROOM R/B)
OK -- REPLACE COMBINATION METER ASSEMBLY