Operation CHARM: Car repair manuals for everyone.

Leak Detection Pump, Checking Vacuum Supply



Fuel System, Checking For Leaks (Passat And Tiguan)

Leak Detection Pump, Checking Vacuum Supply

Special tools, testers and auxiliary items required
- Turbocharger Tester V.A.G 1397A
- T-Piece 251 201 346
- Hose dia. 6 mm

NOTE: Leak detection pump installation location is under wheel housing liner in right rear wheel housing.

- Remove right rear wheel and wheel housing liner.







- Remove vacuum line - 1 - from leak detection pump.
- Connect turbocharger tester V.A.G 1397A with T-piece and 6 mm dia. hose between vacuum line - 1 - and leak detection pump - 2 -.
- Switch on measuring range I (absolute pressure measurement).
- Connect vehicle tester and start engine.
- Select Guided Functions operating mode on vehicle diagnostic tester.
- Select "Check tank ventilation system for leaks" guided function.
- Activate test.
- While the test is running, observe display on turbocharger tester V.A.G 1397A.
- The pressure must pulsate and must not rise above 0.700 bar (absolute pressure) during the test.
- If the pressure rises above 0.700 bar during the test, the vacuum supply is too low. Check vacuum line to intake manifold for kinks or blockage.