Leak Detection Pump, Checking Vacuum Supply
Fuel System, Checking For Leaks (Passat And Tiguan)
Leak Detection Pump, Checking Vacuum Supply
Special tools, testers and auxiliary items required
- Turbocharger Tester V.A.G 1397A
- T-Piece 251 201 346
- Hose dia. 6 mm
NOTE: Leak detection pump installation location is under wheel housing liner in right rear wheel housing.
- Remove right rear wheel and wheel housing liner.
- Remove vacuum line - 1 - from leak detection pump.
- Connect turbocharger tester V.A.G 1397A with T-piece and 6 mm dia. hose between vacuum line - 1 - and leak detection pump - 2 -.
- Switch on measuring range I (absolute pressure measurement).
- Connect vehicle tester and start engine.
- Select Guided Functions operating mode on vehicle diagnostic tester.
- Select "Check tank ventilation system for leaks" guided function.
- Activate test.
- While the test is running, observe display on turbocharger tester V.A.G 1397A.
- The pressure must pulsate and must not rise above 0.700 bar (absolute pressure) during the test.
- If the pressure rises above 0.700 bar during the test, the vacuum supply is too low. Check vacuum line to intake manifold for kinks or blockage.