Fuel Injector: Service Precautions
Fuel Injectors, Cleaning
Special tools, testers and auxiliary items required
• Ultrasonic cleaning unit (VAS 6418)
• Injection module mounting plate (VAS 6418/1)
• Cleaning fluid (VAS 6418/2)
Cleaning
- Remove fuel injectors => [ Fuel Injectors, Removing and Installing ] Fuel Injectors, Removing and Installing.
• Follow the safety precautions and the instructions for the ultrasonic device.
- The ultrasonic device must be filled with cleaning fluid (VAS 6418/2).
• Fill the ultrasonic device up to the upper edge of the holes with cleaner (see the magnified area of the illustration).
- Insert the injector valve - 1 - all the way into the injector module mounting plate (VAS 6418/1) - 2 -.
- Dip the fuel injectors with the injector module mounting plate (VAS 6418/1) into the cleaning device.
- Adjust the temperature to 50 degrees using the knob - 4 -.
- Set a cleaning time of 30 minutes using the knob - 5 -.
- Switch the ultrasonic device on with the button - 3 -.
• The time begins counting down once the cleaning temperature reaches 50 degrees.
- Replace the combustion chamber seal (teflon seal0 after cleaning each fuel injector => [ Teflon Seal on Fuel Injector, Replacing ] Teflon Seal on Fuel Injector, Replacing.
- Then install the fuel injector valves => [ Fuel Injectors, Removing and Installing ] Fuel Injectors, Removing and Installing.