Left Upper A/C Unit Retaining Plate
Left Upper A/C Unit Retaining Plate
Removing
• The Defroster Door Motor (V107) is located on the left upper retaining plate on the A/C unit.
• The lower retaining plate must be removed first before the upper retaining plate can be removed.
- Initiate control motor Basic Setting function with Diagnostic Operation System (VAS 5051B).
- When SF appears on the left of the Climatronic operating display, switch ignition off.
• Control motors can only be re-installed in the service position after removal.
- Remove the lower retaining plate on the left side of the A/C unit. Refer to => [ Left Lower A/C Unit Retaining Plate ] Left Lower A/C Unit Retaining Plate
- Remove the upper retaining plate screws - 3 -.
• To remove the retaining plate the bolts - 1 - are not loosened or removed, they are used for guiding the retaining plate.
• Mark the connections for each motor to prevent confusing them.
- Disconnect connectors.
- Pull retaining plate and control motors out downwards.