PD. Regina #5
PD. Regina #5
REGINA #5 Signal ground missing
Conditions for fault message:
Fault message stored if voltage is above 1.2 Volt.
Causes of fault:
Breakage in wire between Regina #5 and chassis connection
Fault symptom:
None.
PD1
Disconnection of Volvo System Tester
- Disconnect the System Tester according to P1. P1. Connection of Volvo System Tester
^ Continue with Connection of measurement box PD2
PD2
Connection of measurement box
Connect the measurement box to Regina and check the chassis connections according to N1-N2. N. Measurement Box, Signal Description
Check #5 extra carefully.
If the value is OK:
Intermittent fault.
^ Check the connectors for loose connection according to CD. CD. Checking of Wiring
If the value differs:
^ Check the wire between #5 and the chassis connection for breakage according to CD. CD. Checking of Wiring