TK. MFI #20 No Pump Relay Control Signal
TK. MFI#20
MFI#20 No pump relay control signal
Fault message conditions:
The fault message is logged if voltage is above 3 V.
Causes of fault:
Break between MFI#9 and the [1][2]system relay.
[1][2]System relay defective.
Fault symptoms:
The engine will not start.
If the fault is intermittent the engine will stop or run rough.
TK1
Volvo ST, Test box
- Disconnect the ST in accordance with QA2. QA. Connecting The Volvo Scan Tool (ST)
- Connect the test box to MFI and check the GND points in accordance with P1-P2. P. Test Box, Signal Description
^ Continue with Checking the power supply TK2.
TK2
Checking the power supply
- Connect the control module to the test box.
- Install the fuse.
Connect a voltmeter between MFI#20 and MFI#5.
- Try to start the engine.
The voltmeter should read approx. 1 V when the starter motor is operating or the engine running.
If this value is OK:
^ Check the wiring to MFI#9 TK4.
If the reading is incorrect:
^ Test the [1][2]system relay TK3.
TK3
Testing the [1][2]system relay
- Try using a new [1][2]system relay.
Connect a voltmeter between MFI#20 and MFI#5.
- Try starting the engine.
The voltmeter should read approx. 1 V when starter motor is operating or the engine running.
If this value is OK:
^ The [1][2]system relay was sluggish.
If the value still deviates:
^ Check the wiring to MFI#9 TK4.
TK4
Checking the wiring to MFI#9
- Disconnect the IAC valve to isolate MFI#33.
- Ignition on.
Connect a voltmeter between MFI#9 and MFI#5.
The voltmeter should read battery voltage.
If this value is OK:
^ Check for loose contacts in the wiring TK5.
If the reading deviates:
^ Check the wiring between MFI#9 and the [1][2]system relay for breaks in accordance with NA2. NA. Checking the Wiring
TK5
Checking for loose contacts in the wiring
- The IAC valve disconnected.
- Ignition on.
Connect a voltmeter between MFI#9 and MFI#5.
The voltmeter should read battery voltage.
Check that the voltage does not drop to 0 when carrying out a Check for loose contacts in accordance with NA5. NA. Checking the Wiring
If the reading deviates:
Intermittent break:
^ Repair the wiring.
If this value is OK
^ Try using a new control module.