Checking Pump Motor Circuit Resistance to Ground [EL9]
Checking Pump Motor Circuit Resistance To Ground
- Ignition off.
- Disconnect combination relay 4-pin connector.
Connect an ohmmeter between combination relay 4-pin connector terminal 1 and ground.
Ohmmeter should read infinite resistance.
If reading is OK:
- Check pump motor EL10. Checking Pump Motor [EL10]
If reading is incorrect:
- Check lead between pump motor and combination relay 4-pin connector terminal 1 and 3 for short:-circuit to ground as per HA3. Short Circuit to Ground [HA3]
- If leads are OK, try another hydraulic unit as per NE. Hydraulic unit, replacement. Service and Repair