Checking Supply to Pump Motor [EL6]
Checking Supply To Pump Motor
- Ignition off.
- Disconnect control module.
- Connect combination relay 15-pin connector.
- Disconnect combination relay 4-pin connector.
First connect a temporary lead between #1 and #34 on test box.
Then connect another temporary lead between #15 and #1 on test box.
- Ignition on.
Connect a voltmeter between combination relay 4-pin connector terminal 1 and ground.
Voltmeter should read approx. battery voltage.
- Ignition off.
- Remove the temporary leads.
If reading is OK:
- Check ground lead EL8. Checking Ground Lead [EL8]
If reading is incorrect:
- Check control signal to combination relay pump-motor circuit EL7. Checking Control Signal to Combine Relay [EL7]