A/C Condenser Fan Circuit Troubleshooting (With A/C)
A/C Condenser Fan Circuit Troubleshooting
NOTE: Do not use this troubleshooting procedure if the compressor is also inoperative with the A/C on. Refer to the symptom troubleshooting index.
1. Check the No. 47 (30 A) and the No. 10 (7.5 A) fuses in the under-dash fuse/relay box.
Are the fuses OK?
YES - Go to step 2.
NO - Replace the blown fuses, and recheck. If either fuse blows again, check for a short in the No. 47 (30 A) or No. 10 (7.5 A) fuse circuits.
2. Remove the A/C condenser fan relay from the auxiliary under-hood relay box, and test it. Testing and Inspection
Is the relay OK?
YES - Go to step 3.
NO - Replace the A/C condenser fan relay.
3. Measure the voltage between A/C condenser fan relay 4P socket terminal No. 2 and body ground.
Is there battery voltage?
YES - Go to step 4.
NO - Repair open in the wire between the No. 47 (30 A) fuse in the under-dash fuse/relay box and the A/C condenser fan relay.
4. Connect the A/C condenser fan relay 4P socket terminals No. 1 and No. 2 with a jumper wire.
Does the A/C condenser fan run?
YES - Go to step 5.
NO - Go to step 8.
5. Disconnect the jumper wire.
6. Turn the ignition switch to ON (II).
7. Measure the voltage between A/C condenser fan relay 4P socket terminal No. 4 and body ground.
Is there battery voltage?
YES - Repair open in the wire between the A/C condenser fan relay and the ECM/PCM.
NO - Repair open in the wire between the No. 10 (7.5 A) fuse in the under-dash fuse/relay box and the A/C condenser fan relay.
8. Disconnect the jumper wire.
9. Disconnect the A/C condenser fan 2P connector.
10. Check for continuity between A/C condenser fan relay 4P socket terminal No. 1 and A/C condenser fan 2P connector terminal No. 2.
Is there continuity?
YES - Go to step 11.
NO - Repair open in the wire between the A/C condenser fan relay and the A/C condenser fan.
11. Check for continuity between A/C condenser fan 2P connector terminal No. 1 and body ground.
Is there continuity?
YES - Replace the A/C condenser fan motor. Service and Repair
NO - Check for an open in the wire between the A/C condenser fan and body ground. If the wire is OK, check for poor ground at G301.