Power Mirror Actuator Test
Power Mirror Actuator Test
1. Remove the mirror mount cover Power Mirror Replacement.
2. Disconnect the 8P connector (A) from the power mirror actuator (B).
3. Check the actuator operation by connecting battery power and ground according to the table.
4. If the mirror fails to work properly, check for an open or high resistance in the wire between the connector and the mirror holder. If the wire is OK, replace the mirror actuator.
Defogger Test
5. Measure the resistance between terminals No. 1 and No. 3 of the 8P connector. There should be about 7Ohms.
6. If the resistance is not as specified, check for an open or high resistance in the wire between the connector and the mirror holder. If the wire is OK, replace the mirror holder.