Audible Warning Device: Testing and Inspection
Meter Buzzer Circuit Check
Description
- The buzzer for warning chime system is installed in the combination meter.
- The combination meter sounds the alarm buzzer based on the signals transmitted from various units.
Component Function Check
1. CHECK OPERATION OF METER BUZZER
1 Select "BUZZER" of "BCM" on SDT.
2 Perform "LIGHT WARN ALM" of "Active test".
Does meter buzzer activate?
YES
Inspection End.
NO
Replace combination meter. Refer to [Combination Meter: Removal and Installation] Service and Repair.
Diagnosis Procedure
1. CHECK POWER SUPPLY OF COMBINATION METER
Check power supply of combination meter. Refer to [Power Supply and Ground Circuit Check [Combination Meter] Component Tests and General Diagnostics ].
Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace harness.