Checking Ground Lead [EL8]
Checking Ground Lead
- Ignition off.
- Disconnect combination relay 15-pin connector.
Connect an ohmmeter between combination relay 15-pin connector terminal 2 and ground.
Ohmmeter should read approx. 0 Ohms.
If reading is OK:
- Checking pump motor circuit resistance to ground EL9. Checking Pump Motor Circuit Resistance to Ground [EL9]
If reading is incorrect:
- Check lead between combination relays 15-pin connector terminal 2 and ground point 31/44 for open circuit as per HA2. Open Circuit [HA2]