P1800
DTC P1800 VIAS CONTROL SOLENOID VALVE
Component Description
The VIAS control solenoid valve (1) cuts the intake manifold vacuum signal for power valve actuator. It responds to ON/OFF signals from the ECM. When the solenoid is off, the vacuum signal from the intake manifold is cut. When the ECM sends an ON signal the coil pulls the plunger downward and sends the vacuum signal to the power valve actuator.
- : Vehicle front
CONSULT-III Reference Value in Data Monitor Mode
Specification data are reference values.
On Board Diagnosis Logic
The MIL will not illuminate for this self-diagnosis.
DTC Confirmation Procedure
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 11 V at idle.
1. Start engine and let it idle for at least 5 seconds.
2. Check 1st trip DTC.
3. If 1st trip DTC is detected, go to P1800.
Wiring Diagram
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Never use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnosis Procedure
1.CHECK VIAS CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect VIAS control solenoid (1) valve harness connector.
- : Vehicle front
3. Turn ignition switch ON.
4. Check voltage between terminal 1 and ground with CONSULT-III or tester.
Voltage: Battery voltage
OK or NG
OK - GO TO 3.
NG - GO TO 2.
2.DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E12, F3
- Harness for open or short between VIAS control solenoid valve and IPDM E/R
- Repair or replace harness or connectors.
3.CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 29 and VIAS control solenoid valve terminal 2. Refer to Wiring Diagram.
Continuity should exist.
4. Also check harness for short to ground and short to power.
OK or NG
OK - GO TO 4.
NG - Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK VIAS CONTROL SOLENOID VALVE
P1800.
OK or NG
OK - GO TO 5.
NG - Replace VIAS control solenoid valve.
5.CHECK INTERMITTENT INCIDENT
Diagnosis Procedure.
- INSPECTION END
Component Inspection
VIAS CONTROL SOLENOID VALVE
With CONSULT-III
1. Reconnect harness connectors disconnected.
2. Turn ignition switch ON.
3. Perform "VIAS S/V-1" in "ACTIVE TEST" mode.
4. Check air passage continuity and operation delay time under the following conditions.
Without CONSULT-III
Check air passage continuity and operation delay time under the following conditions.
Removal and Installation
VIAS CONTROL SOLENOID VALVE
Component.