Diagnosis Procedure
INTELLIGENT KEY
Diagnosis Procedure
1.CHECK INTELLIGENT KEY BATTERY
Check by connecting a resistance (approximately 300Ohm(s)) so that the current value becomes about 10 mA.
Standard : Approx. 2.5 - 3.0V
Is the measurement value within the specification?
YES - Replace Intelligent Key.
NO - Replace Intelligent Key battery. Description Component Function Check Diagnosis Procedure Component Inspection, "Component Inspection".