Checking Signal Lead (+) [EL14]
Checking Signal Lead (+)
- Ignition off.
- Disconnect combination relay 15-pin connector.
Connect an ohmmeter between combination relay 15-pin connector terminal 8 and #49 on test box.
Ohmmeter should read approx. 0 Ohms.
If reading is OK:
- Check signal lead (-) EL15. Checking Signal Lead (-) [EL15]
If reading is incorrect:
- Check lead between combination relay 15-pin connector terminal 8 and the control module #49 for open circuit as per HA2. Open Circuit [HA2]