Connecting The Breakout Box, Lock And Alarm (VGLA)
Connecting the breakout box, lock and alarm (VGLA)
Connecting the breakout box
- Ignition off.
- Expose the VGLA control module.
- Check the control module connectors and pins visually.
Connect the adapter between the VGLA control module and its connector and connect the breakout box to the adapter, adapter wiring 9511427.
Disconnect the breakout box in reverse order.
Other information
- To access / replace the control module, see VGLA-control module VGLA-Control Module.
- For information about the signals and other values, see Signal specification, lock and alarm, (VGLA) Signal Specification.